PT - JOURNAL ARTICLE AU - Ross, Elaine AU - Purtill, Helen AU - Uszynski, Marcin AU - Hayes, Sara AU - Casey, Blathin AU - Browne, Catherine AU - Coote, Susan TI - Cohort Study Comparing the Berg Balance Scale and the Mini-BESTest in People Who Have Multiple Sclerosis and Are Ambulatory DP - 2016 Sep 01 TA - Physical Therapy PG - 1448--1455 VI - 96 IP - 9 4099 - http://jcore-reference.highwire.org/content/96/9/1448.short 4100 - http://jcore-reference.highwire.org/content/96/9/1448.full SO - Phys Ther2016 Sep 01; 96 AB - Background The Berg Balance Scale (BBS) is a balance measure commonly used for people with multiple sclerosis (MS). The Mini-BESTest is an alternative based on balance systems.Objective The study objective was to compare the BBS and the Mini-BESTest for sensitivity to change, likelihood ratios for walking aid use and falls, and associations with clinical variables in people who have MS and are ambulatory.Design This was a cohort study with measurements before and after exposure to 8 weeks of routine physical therapy intervention.Methods For 52 participants who had a primary diagnosis of MS and who were independently mobile, with or without an aid, demographic details and a history of falls and near falls were collected. Participants completed the Mini-BESTest, Multiple Sclerosis Impact Scale-29, Multiple Sclerosis Walking Scale-12, BBS, Modified Fatigue Impact Scale, and Six-Minute Walk Test.Results No participant started with a baseline Mini-BESTest maximum score of 28, whereas 38.5% (n=20) started with a baseline BBS maximum score of 56. Statistically significant changes in the Mini-BESTest score (X̅=5.31, SD=3.5) and the BBS score (X̅=1.4, SD=1.9) were demonstrated. Effect sizes for the Mini-BESTest and the BBS were 0.70 and 0.37, respectively; standard response means for the Mini-BESTest and the BBS were 1.52 and 0.74, respectively. Areas under the receiver operating characteristic curves for the Mini-BESTest and the BBS were 0.88 and 0.77, respectively, for detecting mobility device use and 0.88 and 0.75, respectively, for detecting self-reported near falls. The Mini-BESTest had a higher correlation for each secondary measure than did the BBS.Limitations This study involved a sample of convenience; 61% of the participants did not use a walking aid. The order of testing was not randomized, and fall status was obtained through retrospective recall.Conclusions The Mini-BESTest had a lower ceiling effect and higher values on responsiveness tests. These findings suggest that the Mini-BESTest may be better at detecting changes in balance in people who have MS, are ambulatory, and have relatively little walking disability.